About Bunsen Burner Labcare
The company was established in 1986 at Ambala Cantt., Haryana, India, with the modern manufacturing facility of laboratory equipments. Most of the Products are manufactured to specification defined by international standards. All have a reputation for quality which is second to none. Company manufacturing units is highly equipped with latest equipment and tools to manufacturer flawless laboratory products, most competitive prices and viability of quality products are our main objects.
Our products are already matchless in the industry due to continuous improvement in quality & workmanship. our innovative nature plays a vital role to improve the things. we also keep improving the quality in tune with the latest development in the international market.
Exceptional Design for Stability and SafetyEngineered with a robust cast iron base, the Labcare B-115 minimizes the risk of tipping, guaranteeing safe operation even during intensive laboratory activities. The slip-resistant bottom and standard cylindrical shape ensure stability on all benchtop surfaces, providing peace of mind for users of any experience level.
Precision Flame Adjustment and Uniform HeatingThis Bunsen burner features a screw-type adjustable collar that enables accurate air intake control, producing a consistent, non-luminous blue flame. Users can easily fine-tune the flame for various laboratory needs, ensuring uniform heating and efficient results in all experimental setups.
Versatile Lab Applications and User-Friendly OperationPerfect for heating, sterilization, and combustion, the Labcare B-115 covers a broad spectrum of laboratory applications. Its manual ignition method, pre-assembled state, and compatibility with LPG or coal gas make it straightforward to use, requiring minimal setup for maximum productivity.
FAQs of Bunsen Burner Labcare:
Q: How do I safely ignite the Labcare Bunsen Burner B-115?
A: To ignite the Labcare B-115 burner, first connect the rubber tubing to the gas inlet and turn on the gas supply. Adjust the screw-type air collar for your desired air flow, then use a spark lighter or match for manual ignition. Always ensure the burner is on a stable, flat surface before lighting.
Q: What is the benefit of the screw-type adjustable collar on this Bunsen burner?
A: The screw-type adjustable collar allows precise control over the air intake, letting you easily fine-tune the flame to achieve a non-luminous, clean blue flame. This provides uniform heating and efficient energy use during experiments.
Q: Where is the Labcare B-115 suitable for use and who can use it?
A: This Bunsen burner is ideal for use in school, college, research, and industrial laboratories. It is suitable for all laboratory age groups, including students and professionals, due to its secure, slip-resistant base and straightforward operation.
Q: What materials and design features enhance the burners durability and performance?
A: The Labcare B-115 is constructed with a chrome-plated brass body and a heavy cast iron base, ensuring corrosion resistance and long-term durability. Its stable, cylindrical shape and round base contribute to reliable, worry-free performance.
Q: How do I control the flame and ensure safe operation during lab experiments?
A: The adjustable air regulator is used to control the quality of the flame, allowing you to obtain a precise, steady blue flame. Always place the burner on a stable surface, use the manual ignition correctly, and never leave the flame unattended.
Q: What types of gases can be used with this Bunsen burner model?
A: The Labcare B-115 is compatible with LPG (liquefied petroleum gas) or coal gas, making it versatile for various laboratory setups.