Back to top
Kjeldahl Distillation Unit
Kjeldahl Distillation Unit

Kjeldahl Distillation Unit

Kjeldahl Distillation Unit Specification

  • Voltage
  • 230V
  • Accuracy
  • 2%
  • Feature
  • Multiple heaters, adjustable heating elements, chemical resistant
  • Power Source
  • Electric, 230V AC
  • Frequency
  • 50 Hz
  • Temperature Range
  • Room temperature to 450C
  • Capacity
  • 500 ml per flask
  • Model No
  • KDU-500
  • Core Components
  • Heater, glass assembly, distillation flask, condenser, stand
  • Measurement Range
  • Up to 100 mg nitrogen
  • Automation Grade
  • Manual
  • Equipment Materials
  • Borosilicate glass, stainless steel stand, PTFE components
  • Type
  • Kjeldahl Distillation Unit
  • Usage
  • Nitrogen estimation/analysis in organic compounds
  • Display Type
  • Analog temperature indicator
  • Dimension (L*W*H)
  • 500 mm x 400 mm x 700 mm
  • Weight
  • Approx. 15 kg
  • Number of Heating Units
  • 3 (Customizable up to 6)
  • Drainage System
  • Integrated PTFE drain for quick disposal
  • Cooling Type
  • Water cooled condenser
  • Glassware Compliance
  • Standard ISI mark
  • Application Area
  • Agriculture, pharmaceutical, food safety laboratories
  • Heater Type
  • Ceramic embedded tubular heater
  • Maximum Power Consumption
  • Approx. 1500W
  • Safety Feature
  • Individual ON/OFF switches for each heater, fuse protection
  • Mounting
  • Bench top
  • Flask Compatibility
  • 500 ml standard Kjeldahl flask
 

Kjeldahl Distillation Unit Trade Information

  • FOB Port
  • MUMBAI
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Letter of Credit (L/C), Paypal, Western Union, Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Delivery Point (DP), Days after Acceptance (DA), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 50 Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • card board packing
  • Main Export Market(s)
  • Western Europe, Australia, North America, South America, Eastern Europe, Middle East, Central America, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO Certified product
 

About Kjeldahl Distillation Unit

This is very useful distillation purpose for 300ml and 500ml capacity flask provided with condenser rack. To work on 220/230 supply.


  • Units of 3 test mantle type (Without glass parts & Clamps)
  • Units of 3 test Heater type (Without glass parts and Clamps)
  • Units of 6 test mantle type (Without glass parts & Clamps)
  • Units of 6 test mantle type (Without glass parts and Clamps)





Advanced Safety and Durability

Equipped with individual ON/OFF switches and fuse protection for each heating unit, the Kjeldahl Distillation Unit ensures safe and reliable operation during critical nitrogen analysis. The body incorporates chemical-resistant materials like borosilicate glass, stainless steel, and PTFE, supporting rigorous laboratory protocols while maintaining long-term durability.


Customizable and Efficient Operation

This unit offers adaptability with 3 heating units, customizable up to 6, and an integrated PTFE drain for streamlined waste disposal. Its ceramic embedded tubular heaters efficiently reach temperatures up to 450C, delivering precise results crucial for quality control in research and industry laboratories.


Comprehensive Compliance and Easy Maintenance

Designed for compatibility with 500 ml ISI-marked flasks, the Kjeldahl Distillation Unit complies with industry standards and is straightforward to maintain. The analog temperature indicator and robust construction facilitate accurate monitoring, while modular assembly simplifies cleaning and routine servicing.

FAQs of Kjeldahl Distillation Unit:


Q: How is nitrogen estimation performed using the Kjeldahl Distillation Unit?

A: Nitrogen estimation involves digesting organic samples in a Kjeldahl flask, followed by distillation in the unit. The released ammonia is then condensed and collected for measurement, enabling precise nitrogen content analysis in various samples.

Q: What types of laboratories commonly use this distillation unit?

A: This unit is ideal for agriculture, pharmaceutical, and food safety laboratories, where reliable and accurate nitrogen analysis is essential for quality control and research purposes.

Q: When should the heating units be customized or upgraded?

A: Customization or upgrading to more heating units (up to 6) is recommended when increased sample throughput or enhanced workflow efficiency is needed in high-demand laboratory environments.

Q: Where can the Kjeldahl Distillation Unit be installed?

A: It is designed for bench-top mounting, making it suitable for most standard laboratory benches. Its compact design and manageable weight allow for flexible installation within workspace constraints.

Q: What safety features ensure secure operation during distillation?

A: Key safety features include individual ON/OFF switches for each heater, fuse protection, and chemical-resistant construction, minimizing risks associated with high-temperature operations.

Q: How is maintenance managed for this unit?

A: Routine maintenance involves cleaning borosilicate glass components and utilizing the integrated PTFE drainage system for efficient waste management, while periodic checks on electrical and heating elements ensure continued performance.

Q: What are the benefits of using a water-cooled condenser in this system?

A: A water-cooled condenser facilitates effective ammonia condensation during distillation, enhancing analytical accuracy and supporting safe laboratory practices by minimizing vapor release.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmacy Instruments Category

B.O.D. Incubator (Low Temperature)

B.O.D. Incubator (Low Temperature)

Model No : BOD250LT

Capacity : 250 Liters

Measurement Range : BOD Measurement in Defined Temperature

Core Components : Refrigeration System, Heating Elements, Digital Temperature Controller

Usage : Laboratories, Research Institutes, Environmental Testing

Automation Grade : Automatic

Fume Hood

Fume Hood

Model No : FHLB Series

Capacity : Approx. 1000 to 1800 mm working length

Measurement Range : Air Velocity: 0.30.5 m/s

Core Components : Motor, Blower, Electrical Panel, Control Valve

Usage : Laboratory chemical ventilation and safety

Automation Grade : SemiAutomatic

Mini Rotary Flask shaker

Mini Rotary Flask shaker

Model No : RS16

Capacity : Max. 5 kg load

Measurement Range : Speed: 20250 rpm

Core Components : Motor, Platform, Timer

Usage : Laboratory mixing of samples in flasks

Automation Grade : Manual

Tissue Culture Rack

Tissue Culture Rack

Model No : TCR100

Capacity : 4 Shelves (customizable up to 6) for multiple culture bottles

Measurement Range : 60 inches height (adjustable)

Core Components : MS frame, trays, fluorescent/cool white lamps, castor wheels

Usage : Plant tissue culture, laboratory applications

Automation Grade : Manual