Back to top
Thermal Conductivity Of Insulator Slab Apparatus
Thermal Conductivity Of Insulator Slab Apparatus
Thermal Conductivity Of Insulator Slab Apparatus
Thermal Conductivity Of Insulator Slab Apparatus
Thermal Conductivity Of Insulator Slab Apparatus
Thermal Conductivity Of Insulator Slab Apparatus

Thermal Conductivity Of Insulator Slab Apparatus

Thermal Conductivity Of Insulator Slab Apparatus Specification

  • Size
  • Standard laboratory bench size
  • Weight
  • Approx. 10-12 kg
  • Style
  • Laboratory Instrument
  • Power Type
  • 230V AC, 50Hz
  • Features
  • Electric heater, temperature sensors, digital voltmeter and ammeter, insulated body
  • Assembly
  • Fully assembled and ready to use
  • Use
  • Measurement of thermal conductivity of insulating materials
  • Model No
  • TIS-TKA-01
  • Surface Finish
  • Powder Coated
  • Type
  • Thermal Conductivity Apparatus
  • Material
  • Mild Steel powder coated body, Insulator slabs (asbestos, cork, or similar)
  • Dimensions
  • 50 cm x 40 cm x 35 cm (approx.)
  • Shape
  • Rectangular with circular test slab section
  • Color
  • Blue and Silver (subject to availability)
  • Function
  • Thermal conductivity analysis
  • Age
  • Suitable for academic institutes, 18+
  • Advantage
  • Accurate and repeatable measurements, easy to operate, suitable for educational and research labs
  • Temperature Sensors
  • 6 thermocouples (chromel-alumel)
  • Digital Display
  • Provided for voltage, current, and temperature indications
  • Heater Capacity
  • 1.0 kW max. (with variable control)
  • Application
  • Physics, Engineering, Material Science laboratory experiments
  • Calibration
  • Factory calibrated, ready to use
  • Test Specimen Diameter
  • 120 mm approx.
  • Insulation
  • High-grade glass wool for minimal heat loss
  • Measurement Range
  • Ambient to 100°C
  • Accessories Included
  • Mains cord, instruction manual, sample insulator slabs
  • Slab Thickness
  • Up to 25 mm
 

Thermal Conductivity Of Insulator Slab Apparatus Trade Information

  • FOB Port
  • MUMBAI
  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 50 Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • CARD BOARD PACKING
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Middle East, Central America, South America, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO CERTIFIED PRODUCT
 

About Thermal Conductivity Of Insulator Slab Apparatus



Experience the splendiferous accuracy of the Top-rated Thermal Conductivity Of Insulator Slab Apparatus, Model No: TIS-TKA-01. Utilise our enviable offer while stocks are limited. Engineered with a lofty standard, this laboratory instrument features a fully assembled, powder-coated mild steel body and a test specimen diameter of approximately 120 mm for precise experimental results. Equipped with digital displays, variable heater control, and six temperature sensors, it delivers accurate and repeatable thermal conductivity analysis from ambient to 100C. Ready for immediate deployment in research, academic, or industrial labs.

Versatile Application Across Sciences

The Thermal Conductivity Of Insulator Slab Apparatus is ideal for Physics, Engineering, and Material Science laboratories. Commonly used by researchers, educators, and students, it facilitates thermal measurements in academic institutes, research centers, and quality control departments. Its robust design assures consistent operation and reliable data, making it a favored choice for universities and technical institutions committed to excellence in experimental learning and research advancement.


Swift Delivery and Sample Availability

Stock is ready and available for immediate dispatching, thanks to efficient transport services. Delivery times are optimized to ensure rapid arrival at your location, supporting your laboratory schedules. Sample specimens are provided with every unit, and our flexible sample policy welcomes your request for product evaluation. Benefit from prompt communication and secure shipment, ensuring a hassle-free purchasing experience for academic and industrial buyers alike.


FAQs of Thermal Conductivity Of Insulator Slab Apparatus:


Q: How does the Thermal Conductivity Of Insulator Slab Apparatus ensure measurement accuracy?

A: The apparatus features six chromel-alumel thermocouples, digital voltage and temperature displays, and offers factory calibration, guaranteeing accurate and repeatable thermal conductivity measurements for insulating materials.

Q: What materials can be tested with this apparatus?

A: This unit is compatible with a variety of insulator slabs, such as asbestos, cork, and similar materials, which are included for experimental versatility in thermal analysis.

Q: Where is the Thermal Conductivity Apparatus typically used?

A: It is commonly used in physics, engineering, and material science laboratories at universities, research centers, and technical institutes for investigative and educational purposes.

Q: What is the benefit of the fully assembled delivery?

A: The apparatus arrives fully assembled and ready to use, minimizing installation effort and allowing users to begin testing immediately upon receipt.

Q: How can a sample be requested and what is the sample policy?

A: Sample insulator slabs are included with every purchase. Additional samples for evaluation purposes can be requested under our flexible sample policy, which supports academic and industrial clients.

Q: When will my order be dispatched?

A: Orders are dispatched promptly from ready-stock inventory using reliable transport services, ensuring minimal delay in product delivery.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Heat Transfer Lab Appartus Labcare-Online Category

Specific Heat Of Air Labcare

Specific Heat Of Air Labcare

Style : Laboratory Equipment

Weight : Approx 12 kg

Age : Suitable for educational and research labs

Dimensions : 600 mm x 300 mm x 350 mm (approx)

Size : Medium bench top

Material : Stainless Steel and Glass

Poll Boiling Apparatus Labcare Online

Poll Boiling Apparatus Labcare Online

Style : Laboratory Instrument

Weight : Approx. 6.5 kg

Age : For Laboratory Use Only

Dimensions : 37 x 17 x 13 cm (Approx.)

Size : Standard Laboratory Size

Material : Mild Steel, Borosilicate Glass, Brass

Thermal Conductivity of Insulator Powered

Thermal Conductivity of Insulator Powered

Style : Rectangular Laboratory Module

Weight : Approx. 3.2 kg

Age : Suitable for all Laboratory Age Groups

Dimensions : 30 cm x 20 cm x 6 cm

Size : Standard Lab Size

Material : PowderCompressed Insulating Material

Parallel flow/counter flow heat Exchanger labcare online

Parallel flow/counter flow heat Exchanger labcare online

Style : Parallel Flow / Counter Flow

Weight : Approx. 45 kg

Age : For Technical and Engineering Students

Dimensions : 1200 mm x 600 mm x 1200 mm (approx)

Size : Compact, Benchtop

Material : Stainless Steel (SS304) and Borosilicate Glass