Back to top
Labtroniks Atomic Absorption Spectrophotometer (Double Beam)
Labtroniks Atomic Absorption Spectrophotometer (Double Beam)

Labtroniks Atomic Absorption Spectrophotometer (Double Beam)

Price 1250000 INR/ Unit

MOQ : 1 Unit

Labtroniks Atomic Absorption Spectrophotometer (Double Beam) Specification

  • Power Source
  • 220V AC
  • Accuracy
  • 0.5% for absorbance
  • Temperature Range
  • Ambient to 45C
  • Measurement Range
  • 0.0001 to 3.000 Abs
  • Capacity
  • 1 ppm to 300 ppm (depends on element)
  • Core Components
  • Hollow cathode lamp, Deuterium lamp, Burner assembly, Photomultiplier tube
  • Voltage
  • 220V
  • Model No
  • LT-AA201
  • Frequency
  • 50/60 Hz
  • Feature
  • Microprocessor controlled, flame and graphite furnace, RS232/USB interface
  • Automation Grade
  • Semi-automatic
  • Equipment Materials
  • Powder coated steel frame, corrosion-resistant components
  • Type
  • Double Beam Atomic Absorption Spectrophotometer
  • Usage
  • Elemental analysis in laboratory and industrial applications
  • Display Type
  • Graphical LCD Display
  • Dimension (L*W*H)
  • 830 x 550 x 480 mm
  • Weight
  • Approx. 48 kg
  • Sample Introduction
  • Flame and graphite furnace
  • Calibration
  • Multi-point Calibration with Curve Fitting
  • Fuel Gases
  • Air/Acetylene or Nitrous Oxide/Acetylene
  • Burner Head
  • Titanium, 100 mm
  • Light Source
  • Hollow Cathode and Deuterium Lamp
  • Power Consumption
  • 350 VA
  • Wavelength Accuracy
  • 0.1 nm
  • Wavelength Range
  • 190 - 900 nm
  • Wavelength Repeatability
  • 0.05 nm
  • Background Correction
  • Deuterium Lamp/Zeeman Effect (optional)
  • Detector
  • Photomultiplier Tube
  • Photometric Range
  • -0.3 to 3.0 Abs
  • Operating System Compatibility
  • Windows-based Software Included
  • Slit Width
  • Selectable: 0.2, 0.4, 1.0, 2.0 nm
  • Lamp Turret Capacity
  • 8 Lamps
  • Data Interface
  • USB, RS232C
  • Safety Features
  • Flame Failure Protection, Over-temperature Protection
  • Sensitivity
  • 0.02 g/ml (Cu)
  • Spray Chamber
  • Corrosion Resistant Polypropylene
 
 

About Labtroniks Atomic Absorption Spectrophotometer (Double Beam)

LT 790 DIGITAL ANALYZER


The LT 790 Digital Analyzer is a compact laboratory testing instrument designed for accurate and reliable sample analysis. It is suitable for laboratories, educational institutes, research centers, and industrial testing applications.


FEATURES:

Digital testing system

Compact tabletop design

Easy operation

Stable performance

Energy-efficient operation

Durable construction


APPLICATIONS:

Laboratory testing

Research laboratories

Educational institutes

Industrial quality testing

Scientific analysis applications


BENEFITS:

Fast and accurate results

User-friendly operation

Compact and durable design

Smooth and efficient performance



Advanced Double Beam Technology

Equipped with a double-beam optical system, the LT-AA201 delivers higher stability and consistency during analysis by simultaneously measuring both sample and reference beams. This results in minimized drift and improved signal accuracy, making it an ideal choice for laboratories that demand reliable and repeatable elemental quantification.


User-Friendly Operation and Software

The spectrophotometer features intuitive Windows-based software for streamlined operation, calibration, and data management. The graphical LCD display offers clear visualization of results, and its semi-automatic controls make setup straightforward, reducing training time for new operators and enhancing workflow efficiency in busy analytical environments.


Enhanced Safety and Durability

Safety is prioritized with built-in flame failure and over-temperature protection systems. Engineered from powder-coated steel and corrosion-resistant components, this instrument is designed to withstand harsh laboratory conditions. With features such as a titanium burner head and robust construction, users are assured dependable performance and extended instrument lifespan.

FAQ's of Labtroniks Atomic Absorption Spectrophotometer (Double Beam):


Q: How does the double-beam system enhance measurement accuracy in the Labtroniks Atomic Absorption Spectrophotometer?

A: The double-beam optical system allows the instrument to measure the sample and reference simultaneously, effectively compensating for fluctuations in lamp intensity and minimizing drift. This leads to more stable absorbance readings and improved accuracy during elemental analysis.

Q: What types of samples can be introduced into the LT-AA201 and through which methods?

A: Samples can be introduced using both flame and graphite furnace techniques, allowing analysis of a wide range of sample types including liquids, biological fluids, and environmental samples. The system's titanium burner enables robust flame atomization, while the graphite furnace is suitable for trace-level detection.

Q: When should I use background correction, and which options are available on this spectrophotometer?

A: Background correction is recommended when analyzing samples with complex matrices or where spectral interferences are expected. The LT-AA201 offers background correction via a deuterium lamp or optional Zeeman effect, ensuring more accurate measurement of the target analyte in the presence of potential interfering substances.

Q: Where is this spectrophotometer typically used and what industries benefit from it?

A: This model is widely used in laboratories and industries such as environmental monitoring, metallurgy, food safety, pharmaceuticals, and chemical analysis. Its robust design caters to both research institutions and quality control settings that require sensitive and high-throughput elemental analysis.

Q: What is the calibration process for the Labtroniks LT-AA201?

A: The instrument employs a multi-point calibration process with curve fitting, allowing users to generate accurate calibration curves for different analytes. The provided Windows-based software guides users through the calibration steps, making the procedure straightforward and ensuring reliable quantification results.

Q: How is data exported from the spectrophotometer for further analysis or record-keeping?

A: Data can be transferred through USB and RS232C interfaces, facilitating easy integration with laboratory information management systems or external computers for further analysis, storage, and reporting.

Q: What are the main benefits of using the Labtroniks Atomic Absorption Spectrophotometer in routine elemental analysis?

A: Key benefits include high sensitivity (0.02 g/ml for Cu), extensive photometric and wavelength ranges, rapid sample introduction, comprehensive safety features, and robust construction. The combination of automation, precision, and user-friendly controls makes the LT-AA201 suitable for demanding and routine analytical tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCIENCE LAB EQUIPMENT Category

AMMETER (MO-64) By Labcare

AMMETER (MO-64) By Labcare

Price 220 INR / Piece

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Feature : Shock resistant, zero adjuster

Core Components : Moving coil mechanism, scale, pointer

Weight : Approx. 400 g

AMMETER (MO-66) By Labcare

AMMETER (MO-66) By Labcare

Price 550.00 INR / Piece

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Feature : Clear Scale, Fine Calibration, Durable Construction

Core Components : Moving Coil, Magnet, Scale, Pointer

Weight : Approx. 200 grams

BALANCE DIGITAL

BALANCE DIGITAL

Price 1400.0 INR / Piece

Minimum Order Quantity : 1 Piece

Automation Grade : SemiAutomatic

Feature : Tare Function, Overload Protection, Auto Calibration

Core Components : Load cell, Microcontroller

Weight : Approx. 2.5 kg

AMMETER (MO-67) By Labcare

AMMETER (MO-67) By Labcare

Price 700.0 INR / Piece

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Feature : Shock Resistant, Clear Marking, Durable

Core Components : Moving Coil, Magnet, Needle, Scale

Weight : Approx. 250 g