Labtroniks Touch Screen Microprocessor Flame Photometer Specification

  • Model No
  • LT 6710
  • Feature
  • Touch screen operation, auto ignition, data storage, printer interface, USB port
  • Temperature Range
  • Ambient to 800C
  • Voltage
  • 230 V
  • Automation Grade
  • Semi-automatic
  • Measurement Range
  • Na: 0-100 ppm, K: 0-100 ppm, Ca: 0-100 ppm, Li: 0-100 ppm
  • Power Source
  • 230V AC, 50Hz
  • Frequency
  • 50 Hz
  • Core Components
  • Microprocessor, Burner System, Compressor
  • Capacity
  • Up to 100 samples/hour
  • Accuracy
  • 1% for Na, K
  • Equipment Materials
  • Powder coated metal with chemical resistant parts
  • Type
  • Microprocessor Flame Photometer
  • Usage
  • Laboratory, Clinical, and Industrial analysis
  • Display Type
  • 7-inch TFT Color Touch Screen
  • Dimension (L*W*H)
  • 420 x 340 x 340 mm
  • Weight
  • Approx 15 kg
  • Printer Interface
  • Compatible with thermal and dot matrix printers
  • Ignition System
  • Automatic with safety interlocks
  • Operating Temperature
  • 15C to 40C
  • Sample Aspiration Rate
  • 8 to 10 ml/min
  • Readout
  • Concentration and emission intensity
  • Data Storage
  • Stores up to 1000 sample results
  • User Interface
  • Icon-based graphical user interface
  • Element Selection
  • Push button selection for Na, K, Ca, Li
  • Flame Type
  • LPG and Air
  • Calibration
  • 2-point calibration for each element
  • Gas Supply
  • Requires LPG (regulator included)
  • Safety Features
  • Flame safety device, auto shut-off
 
 

Labtroniks Touch Screen Microprocessor Flame Photometer About

TOUCH SCREEN MICROPROCESSOR FLAME PHOTOMETER

The Touch Screen Microprocessor Flame Photometer is a high precision analytical instrument designed for the rapid and accurate determination of alkali and alkaline earth metal elements in liquid samples. Equipped with an advanced touch screen interface and microprocessor controlled operation, it provides reliable, repeatable, and efficient analysis for research, pharmaceutical, agricultural, environmental, and industrial laboratories.

FEATURES

Advanced touch screen display

Microprocessor controlled operation

High sensitivity flame detection system

Accurate elemental analysis

Fast sample measurement

Automatic calibration function

Stable and reliable performance

User friendly interface

Data storage and USB connectivity

Compact and durable construction

APPLICATIONS

Research laboratories

Pharmaceutical industries

Clinical laboratories

Agricultural laboratories

Soil and water analysis

Food and beverage testing

Environmental monitoring

Industrial quality control

BENEFITS

Accurate and repeatable results

Fast analytical performance

Easy operation and maintenance

Reliable long term stability

Suitable for routine laboratory analysis

High productivity and efficient workflow


Advanced Performance and Precision

Equipped with a microprocessor and high-quality burner system, the LT 6710 delivers accurate measurement for Na, K, Ca, and Li with a precision of 1%. The 2-point calibration for each element ensures reliable results, making it indispensable for rigorous laboratory and industrial testing applications.


User-Friendly Touch Screen Interface

The 7-inch TFT color touch screen, along with an intuitive icon-based graphical user interface, simplifies setup and operation. Users can quickly select elements via push buttons and navigate through different functionalities, improving workflow efficiency and minimizing the learning curve for new users.


Robust Safety and Data Management

Safety interlocks, flame safety devices, and auto shut-off mechanisms safeguard users during operation. With the capacity to store and manage up to 1000 sample results, and direct printing options via USB or printer interface, the photometer streamlines data handling and reporting.

FAQ's of Labtroniks Touch Screen Microprocessor Flame Photometer:


Q: How does the Labtroniks Touch Screen Microprocessor Flame Photometer ensure operational safety?

A: This flame photometer integrates multiple safety features, including an automatic ignition system with safety interlocks, a flame safety device, and auto shut-off for enhanced protection during analysis. These safety mechanisms help prevent mishaps associated with flame operation and provide peace of mind during extended usage.

Q: What is the process for calibrating this flame photometer before measurements?

A: The instrument utilizes a 2-point calibration for each element (Na, K, Ca, Li). Users simply follow on-screen prompts to input calibration standards, ensuring precise and reliable readings for every session.

Q: When should data be exported or printed, and how is this achieved?

A: Sample data can be exported or printed at any stage using the integrated printer interface, which supports both thermal and dot matrix printers. The device stores up to 1000 results, making it easy to batch print or export data as needed for record-keeping and quality control.

Q: Where can the Labtroniks LT 6710 be utilized effectively?

A: This model is engineered for use in laboratories, clinical settings, and industrial analysis, thanks to its robust construction, chemical-resistant parts, and precise measurement capabilities. Its versatile design allows it to handle a variety of testing environments with ease.

Q: What is the benefit of using the touch screen and icon-based interface?

A: The 7-inch TFT color touch screen with an icon-based graphical interface streamlines operation, reduces setup time, and helps users of all proficiency levels easily navigate the device's extensive functions.

Q: How is the sample aspiration rate managed and what advantage does it offer?

A: The flame photometer aspirates samples at a rate of 8 to 10 ml/min, which provides consistent sample introduction for optimal accuracy and throughput, making it suitable for high-volume testing environments.

Q: What makes this photometer advantageous for high-throughput laboratories?

A: With the ability to process up to 100 samples per hour, high data storage capacity, semi-automatic features, and compatibility with fast data output devices, the LT 6710 offers significant efficiency improvements for laboratories handling large sample loads.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in LABTRONIKS Category

Labtroniks Microprocessor Disintegration Test Apparatus (2 Basket

Labtroniks Microprocessor Disintegration Test Apparatus (2 Basket

Price 57000.0 INR / Set

Minimum Order Quantity : 1 Set

Equipment Materials : Stainless steel and highgrade transparent acrylic

Accuracy : 0.1C for temperature, 1 sec for timing

Frequency : 50 Hz

Core Components : Microprocessor controller, baskets, beakers, digital display

Labtroniks Digital Flame Photometer (Dual Channel)

Labtroniks Digital Flame Photometer (Dual Channel)

Price 37000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Equipment Materials : Corrosion resistant metal body with powder coating

Accuracy : 2% for Sodium and Potassium

Frequency : 50 Hz

Core Components : Flame burner, Nebulizer, Photodetector, Filters, Digital display, Air compressor

Double Beam UV/VIS spectrophotometer (Xenon Lamp)

Double Beam UV/VIS spectrophotometer (Xenon Lamp)

Price 250000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Equipment Materials : Metal and HighGrade Plastic Housing

Accuracy : 0.3% T

Frequency : 50/60 Hz

Core Components : Xenon Lamp, Detectors, Optics, Cuvette Holder, Display Panel

Labtroniks Digital Spectrophotometer (Double Display)

Labtroniks Digital Spectrophotometer (Double Display)

Price 34000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Equipment Materials : Sturdy ABS Body

Accuracy : 0.5% T or better

Frequency : 50/60 Hz