Back to top
Tablet Hardness Tester Labcare
Tablet Hardness Tester Labcare

Tablet Hardness Tester Labcare

Tablet Hardness Tester Labcare Specification

  • Measurement Range
  • 05 Kg
  • Voltage
  • Not Required (Manual)
  • Power Source
  • Manual
  • Model No
  • Labcare-THT
  • Temperature Range
  • Ambient
  • Capacity
  • 5 Kg
  • Core Components
  • Load Cell, Pointer Scale, Mechanical Lever
  • Feature
  • Simple and Accurate Measurement, Portable Design
  • Automation Grade
  • Manual
  • Accuracy
  • 0.1 Kg
  • Frequency
  • 50 Hz
  • Equipment Materials
  • Stainless Steel & Plastic Body
  • Type
  • Tablet Hardness Tester
  • Usage
  • Pharmaceutical Laboratory
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • 250 x 90 x 90 mm (Approx.)
  • Weight
  • 2.5 Kg (Approx.)
  • Hardness Measuring Unit
  • Kg/cm2
  • Sample Type
  • Round and Irregular Shaped Tablets
  • Color
  • White & Blue
  • Calibration
  • User Calibrated
  • Application
  • Quality Control in Pharma/Bio Labs
  • Max. Tablet Diameter
  • Up to 30 mm
  • Testing Method
  • Pressure Applied via Plunger
  • Reading Type
  • Direct Reading on Scale
  • Cleaning
  • Easy to Clean with Mild Detergent
 

Tablet Hardness Tester Labcare Trade Information

  • FOB Port
  • Mumbai
  • Payment Terms
  • Cash on Delivery (COD), Letter of Credit (L/C), Western Union, Paypal, Delivery Point (DP), Letter of Credit at Sight (Sight L/C), Cash Against Delivery (CAD), Telegraphic Transfer (T/T), Days after Acceptance (DA), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 50 Per Week
  • Delivery Time
  • 1 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • PACK IN WELVET BOX.
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO CERTIFIED PRODUCTS MSME CERTIFIED PRODUCTS
 

About Tablet Hardness Tester Labcare

Product Description

With a firm commitment to quality, we are offering a broad spectrum of Tablet Hardness Tester. This tester is used to test tablet hardness quickly, accurately and conveniently. The instrument is ideal for tablet hardness testing very handy and portable, records quick and directly on dial indicator. To offer our valuable patrons a top-notch range, our deft professionals manufacture this tester using quality assured components with the help of modern methodology.

Features:

  • Scale adjustable for 0 setting as per size of the tablets
  • Precise result
  • High functionality

Other Details:
  • (Monsanto Type) : A fairly and handy instrument for tacking quick reading for the hardness of tablets. It is made of brass urned parts, heavily chrome plated. The scale is 0 to 20 Kgs. The index mark and division is in 1 Kg reading. Scale adjustable for 0 setting as per size of the tablets.
  • (PFIZER Type) :To test tablet hardness quickly, accurately and conveniently. The instrument is ideal for tablet hardness testing very handy and portable, records quick and directly on dial indicator. The hardness reading with accuracy of 0.5 Kgs., upto 20 Kgs.


Effortless and Accurate Tablet Hardness Testing

The Labcare Tablet Hardness Tester employs a simple yet robust mechanism, utilizing pressure applied by a plunger to determine a tablets hardness. With its direct analog scale and user-calibrated system, laboratory professionals can quickly and reliably obtain measurements within the 05 Kg range. Its accuracy and straightforward operation contribute to repeatable, dependable results crucial for pharmaceutical quality control.


Designed for Versatility and Durability

Accommodating various tablet shapes and sizes up to 30 mm in diameter, this tester features a resilient stainless steel and plastic body. Its compact dimensions and manual, power-free operation ensure portability and easy integration into any laboratory environment. Regular cleaning with mild detergent is simple, upholding strict hygiene standards essential in pharmaceutical and bioscience applications.

FAQs of Tablet Hardness Tester Labcare:


Q: How do I operate the Labcare Tablet Hardness Tester?

A: To use the tester, place the tablet between the plunger and anvil, then manually apply pressure via the mechanical lever. The load cell transfers force to the pointer scale for a direct reading in Kg/cm. No external power source is needed, ensuring ease of operation during routine quality checks.

Q: What types and sizes of tablets can this tester accommodate?

A: The Labcare Tablet Hardness Tester is suitable for both round and irregularly shaped tablets with a maximum diameter of up to 30 mm. This flexibility allows it to be used for a wide range of pharmaceutical tablet formulations and sizes.

Q: When should I calibrate the hardness tester, and how is it done?

A: Calibration should be carried out before initial use or whenever consistent results are in question. User calibration is straightforward; follow the manuals instructions to adjust the scale using standard weights, ensuring accuracy for all subsequent measurements.

Q: Where is this tester typically used?

A: This device is primarily used in pharmaceutical and biotechnology laboratories across India for quality control purposes. Its robust construction and portable design also make it suitable for production sites, research facilities, and educational settings.

Q: What is the benefit of using a manual analog tester over a digital tester?

A: Manual analog testers like the Labcare model do not require electricity or batteries, providing reliable performance even where power supplies are inconsistent. They offer immediate, direct readings with minimal maintenance, making them ideal for routine and field use.

Q: How do I clean and maintain the Labcare Tablet Hardness Tester?

A: For regular maintenance, clean the stainless steel and plastic surfaces with a soft cloth and mild detergent. Avoid abrasive cleaners to maintain accuracy and longevity. Routine cleaning is important to meet strict pharmaceutical lab standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmacy Instruments Category

Tissue Culture Rack

Tissue Culture Rack

Automation Grade : Manual

Feature : Energy efficient, rustproof, easy assembly & movement, adjustable shelves

Core Components : MS frame, trays, fluorescent/cool white lamps, castor wheels

Equipment Materials : High grade mild steel powder coated with stainless steel trays

Frequency : 50 Hz

Usage : Plant tissue culture, laboratory applications

Refrigerated Water Bath (Low Temperature)

Refrigerated Water Bath (Low Temperature)

Automation Grade : SemiAutomatic

Feature : Rapid Cooling, Uniform Temperature Distribution, Overtemperature Protection

Core Components : Refrigeration Compressor, Circulation Pump, Digital Temperature Controller

Equipment Materials : Stainless Steel Chamber with Powder Coated Outer Body

Frequency : 50 Hz

Usage : Laboratory, Research, Quality Control

Autoclave Portable

Autoclave Portable

Automation Grade : Manual

Feature : Portable design Highpressure sterilization

Core Components : Stainless Steel Pressure Gauge

Equipment Materials : Stainless Steel

Frequency : 50 Hz

Usage : Medical Laboratory Industrial

Vertical Laminar Airflow Cabinet

Vertical Laminar Airflow Cabinet

Automation Grade : SemiAutomatic

Feature : Provides sterile and particlefree working area

Core Components : Blower HEPA Filter Motor

Equipment Materials : Stainless Steel

Frequency : 50 Hz

Usage : Laboratory